Conventional fire alarm control panel. Six (6) Zones :

  • Maximum number of Fire Detectors Inputs: 20 detectors for each zone
  • Has 4 outputs: Sounder/ Fire protection/ Fire routing/ Fault routing
  • Auxiliary resettable power output: 24VDC/ 100mA limiting protection
  • User friendly interface for easy operation and recognition
  • Access levels to enter the panel
  • Fault supervision and notification: inputs, outputs, system, power, earth, fuse

The AW-CFP2166 series 2 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Technical parameters

AC INPUT 220VAC 50HZ +10%
-15%
DC OUTPUT 24VDC typical
Voltage for MCU 5V for power board MCU, 3.3V for others
Current at 24VDC from PSE 450mA standby current
Maximum current from PSE 2A except batteries charge
Batteries current 1.85A maximum, current limited
Auxiliary output 24VDC +/- 10%, 100 mA max,
current limited, monitored
Batteries 2*12V/ 2.3Ah sealed lead acid gel,
self-regulated
2*12V/ 7Ah if needed
Battery replace Resistance 2Ω±10% if needed
Battery low-voltage protection 22.2V
Detectors connection allowed each zone 20 (except MCPs)
Zone alarm current 6mA minimum/ 27mA maximum
Sounder output 2*0.75A maximum
Fire protection 100mA maximum
Fire routing 100mA maximum
Fault routing 100mA maximum
Communication protocol 2 wires RS485 bus system
Relay contacts rating Dry contacts (NO/NC) 1A @24VDC
EOL resistor for zone 6.8K 1W
EOL resistor for outputs 6.8K 1W
Fuse on power board 3A/ 250V glass tube fuse 20mm
Fuse on EMI board 1A/ 250V glass tube fuse 20mm
Environmental Class A temperature range: -5 to 40°C (23~104°F)
Humidity: 5 to 95% RH, non-condensing
Terminal blocks rating All terminals rated for 12 to18 AWG
(0.75 to 2.5 mm2)

Ready to ship in 1-2 weeks


Informations complémentaires

Poids 5 kg
Be the first to review “Wired Conventional fire alarm control panel AW-CFP2166-6B. Six (6) Zones”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Reviews

There are no reviews yet.

Conventional fire alarm panel User Manual

Download

This manual explains, in a step-by-step manner, the procedure for the installation of the Fire Alarm Control Panel

Vendor Information

  • Store Name: Barclés
  • Vendor: Barclés
  • No ratings found yet!

See It Styled On Instagram

    No access token
Translate »

Main Menu